The AuraFlame is not only focused on style with its arched door design, but also on practicality. This assures you of a clean, thorough burn, and even allows you to control the amount of firewood burned. Available with either Black or Gold Plated cast iron doors.

Standard Features
  90,000 Btu's
  73% Efficiency
  Secondary Combustion System
   Air Seal Cast Iron Doors
  8" Clay Flue Adaptor
  4" Outside Air Flex Pipe
  Borofloat Safety Glass ( (2) 16½" x 11")
  Chimney Damper Control
  Combustion Air Damper Control
  Ajustable Legs
  20 Year Limited Warranty


Optional Features

  Gold Plated Cast Iron or Black Cast Iron Arched Doors
  Black Upper and Lower Grills
  Brass Upper and Lower Grills
  Arched Face Trim - Brass
  Arched Door Trim - Brass
  Brick-in Fan w/ Variable Speed Control (450 CFM)
  Outside Combustion Air Vent
  Ash Chute & Cover
  Outside Clean Out Door
  Top Plate w/ Precut Center Hole
  Arched Lintel Iron
  8" Round Stack Pipe - Straight
  5", 10" & 14 1/2" Offset Stacks
  8" Round Metal Chimney Adaptor for use with 8" HT, Class "A", Metal Chimney


  From Unit Sides to Face brick: 3/8"
  From Unit Top to Face Brick: 1/2"
  From Unit Back/Sides to Block Enclosure: 4"
  From Block Enclosure to Exterior Walls: 4"
   From Top of Grill Opening to Ceiling: 17"
  From Fuel Door to Combustion Mantel: 16"
  From Fuel Door to Side Wood Mantel: 8"
  From Side of Fuel Opening to Adjacent Wall: 24""
  From Top Slab to Wooden Header: 12""
  YOU MUST Cover Top Slab w/ 6" Non-Faced Fiberglass Insulation
  From Wooden Header to Chimney Block: 2"
  From 10" Stack Pipe to Bottom of Top Slab: 1"

Always consult the installation manual for venting requirements
 REQUIRED CHIMNEY TERMINATION
 4" Outside Air Flex Pipe Kit for Chamber only -(included w/ unit) (connects intake air on fireplace to 4"-30 gauge galv. pipe)
 30 Gauge Galvanized Pipe (minimum thickness) (adapts 4" flex pipe at chamber wall to outside air vent)
 Maximum Termination - 26'
 Runs up to 10' - Pipe Size - 4"
 Runs Between 10' - 26' - Pipe Size - 6"
 Elbows - Maximum - 3
 Do Not Terminate into Attic or Garage
 3' Clearance Below Chimney if Terminating Beside Chase"
 OUTSIDE AIR TERMINATION
 8", HT, Class "A", 2100 , Insulated Double Wall Metal Chimney OR
 9" x 13" Clay Flue
 Minimum Height - 10'
 30 Angle Maximum Offsets

  231 auraflame manual
  231 auraflame line drawing
  231 auraflame brochure
  Tested by Warnock Hersey and complies with U.L. standard 127 (7/90) and CAN/ULC-S610-M87
   EPA exempt
   Air seal doors
   Ceramic glass
   Intake & exhaust air dampers
   

100% outside air for combustion